Application scenarios: A Qingdao energy company's current exhaust temperature is 120℃. The waste gas at this temperature is directly treated resulting in heat loss. High temperature Waste gas is recycled through Waste heat recovery device to heat and remove salt water to reduce the loss of self-use steam.
Treatment scale: 80t/h steam boiler, system treatment waste gas volume of 90000m³/h, temperature 120℃.
Transformation technology: The waste heat recovery unit was used to heat and remove brine
Construction scope: Including system design, equipment supply, on-site installation and debugging of the whole Waste Heat Recovery system EPC project (excluding civil construction)
Using effect: Raise the brine temperature to 45 ° C. The consumption of self-used steam can save about 2.8t/h, and the investment cost can be recovered after running for one and a half years.
Bleaching of flue gas of mixer in asphalt plant
Boiler flue gas bleaching
Bleaching of molding machine flue gas
Coking flue gas bleaching
Primary air preheating of boiler
Flue gas waste heat heating demineralized water
Heating oven exhaust air
Dyeing wastewater heating dyeing tank water
Phase change condenser
Natural gas heater
SGH steam heater
High viscosity gas-liquid heater
Drive type air cooler
High efficiency air preheater
High efficiency waste heat recovery device